Part Number Hot Search : 
16101BAN 065ET0 GMS2301 IRF5210L SL900 DFCLJ FDG63 AS4C4M4
Product Description
Full Text Search
 

To Download D4NL-1DFG-B Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  g-153 d4nl d4nl guard lock safety-door switch d4nl lead-free, environment-friendly design  contains no harmful substances, such as lead or cad- mium, reducing the burden on the environment.  models with 4-contact and 5- contact built-in switches are available.  key holding force of 1,300 n min.  can be used for either standard loads or microloads.  lineup includes models with a conduit size of m20.  ip67 degree of protection.  operation key compatible to d4ds, d4ns and d4gl. model number structure model number legend switch 1. conduit size 1: pg13.5 2: g1/2 4: m20 2. built-in switch (with door open/closed detection switch and lock monitor switch contacts) a: 1nc/1no slow-action contacts plus 1nc/1no slow-action contacts b: 1nc/1no slow-action contacts plus 2nc slow-action con- tacts c: 2nc slow-action contacts pl us 1nc/1no slow-action con- tacts d: 2nc slow-action contacts pl us 2nc slow-action contacts e: 2nc/1no slow-action contacts plus 1nc/1no slow-action contacts f: 2nc/1no slow-action contacts plus 2nc slow-action con- tacts g: 3nc slow-action contacts plus 1nc/1no slow-action con- tacts h: 3nc slow-action contacts pl us 2nc slow-action contacts 3. head mounting direction and material f: four mounting directions possible (front-side mounting at time of delivery)/plastic d: four mounting directions possible (front-side mounting at time of delivery)/metal 4. door lock and release a: mechanical lock/24-vdc solenoid release b: mechanical lock/110-vac solenoid release c: mechanical lock/230-vac solenoid release g: 24-vdc solenoid lock/mechanical release h: 110-vac solenoid lock/mechanical release j: 230-vac solenoid lock/mechanical release 5. indicator b: 10 to 115 vac/vdc (orange led indicator) e: 100 - 230v vac (orange neon lamp indicator) 6. release key type blank:standard 4: special release key 7. release key position blank:bottom s: front operation key \ 1. operation key type 1: horizontal mounting 2: vertical mounting 3: adjustable mounting (horizontal) 5: adjustable mounting (horizontal/vertical) 12 3 4 5 6 7 d4nl- @@@@ - @@@ 1 d4ds-k @ f502-en2-04.book seite 153 di enstag, 26. juli 2005 5:48 17
g-154 safety sensors / components ordering information list of models for 110v and 230v version ask your local omron representative switches (operation keys are sold separately.) head material release key position release key type solenoid voltage/ indicator lock and release types contact configuration (door open/closed detection switch and lock monitor switch contacts) (slow-action) approved direct opening nc contact conduit opening model plastic bottom standard solenoid: 24 vdc orange led: 10 to 115 vac/vdc mechanical lock solenoid release 1nc/1no+1nc/1no pg13.5 d4nl-1afa-b* g1/2 d4nl-2afa-b m20 d4nl-4afa-b* 1nc/1no+2nc pg13.5 d4nl-1bfa-b g1/2 d4nl-2bfa-b m20 d4nl-4bfa-b 2nc+1nc/1no pg13.5 d4nl-1cfa-b* g1/2 d4nl-2cfa-b m20 d4nl-4cfa-b* 2nc+2nc pg13.5 d4nl-1dfa-b g1/2 d4nl-2dfa-b m20 d4nl-4dfa-b 2nc/1no+1nc/1no pg13.5 d4nl-1efa-b g1/2 d4nl-2efa-b m20 d4nl-4efa-b* 2nc/1no+2nc pg13.5 d4nl-1ffa-b g1/2 d4nl-2ffa-b m20 d4nl-4ffa-b 3nc+1nc/1no pg13.5 d4nl-1gfa-b g1/2 d4nl-2gfa-b m20 d4nl-4gfa-b 3nc+2nc pg13.5 d4nl-1hfa-b g1/2 d4nl-2hfa-b m20 d4nl-4hfa-b solenoid lock mechanical release 1nc/1no+1nc/1no pg13.5 d4nl-1afg-b* g1/2 d4nl-2afg-b m20 d4nl-4afg-b* 1nc/1no+2nc pg13.5 d4nl-1bfg-b g1/2 d4nl-2bfg-b m20 d4nl-4bfg-b 2nc+1nc/1no pg13.5 d4nl-1cfg-b* g1/2 d4nl-2cfg-b m20 d4nl-4cfg-b* 2nc+2nc pg13.5 D4NL-1DFG-B g1/2 d4nl-2dfg-b m20 d4nl-4dfg-b 2nc/1no+1nc/1no pg13.5 d4nl-1efg-b g1/2 d4nl-2efg-b m20 d4nl-4efg-b* 2nc/1no+2nc pg13.5 d4nl-1ffg-b g1/2 d4nl-2ffg-b m20 d4nl-4ffg-b 3nc+1nc/1no pg13.5 d4nl-1gfg-b g1/2 d4nl-2gfg-b m20 d4nl-4gfg-b 3nc+2nc pg13.5 d4nl-1hfg-b g1/2 d4nl-2hfg-b m20 d4nl-4hfg-b : models with approved direct opening contacts. prefered stock item* f502-en2-04.book seite 154 di enstag, 26. juli 2005 5:48 17
g-155 d4nl d4nl operation keys specifications standards and ec directives applicable ec directives and standards  machinery directive  low voltage directive  en1088  en60204-1  gs-et-19 approved standards note: 1. consult your omron representative for details. 2. approval for csa c22.2 no. 14 is authorized by the ul mark. approved standard ratings tv (en60947-5-1) note: use a 10-a fuse type gi or gg that conforms to iec 269 as a short-circuit protection device. this fuse is not built in to the switch. ul/csa (ul508, csa c22.2 no. 14) a300 solenoid coil characteristics indicator characteristics type model d4ds-k1 d4ds-k2 d4ds-k3 d4ds-k5 horizontal mounting vertical mounting adjustable mounting (horizontal) adjustable mounting (horizontal/vertical) agency standard file no. tv product service en60947-5-1 (approved direct opening) (see note 1.) ul (see note 2.) ul508, csa c22.2 no.14 e76675 item utilization category ac-15 dc-13 rated operating current (i e ) 3 a 0.27 a rated operating voltage (u e ) 240 v 250 v rated voltage carry current current volt-amperes make break make break 120 vac 10 a 60 a 6 a 7,200 va 720 va 240 vac 30 a 3 a item 24 vdc 110 vac 230 vac rated operating voltage (100% ed) 24 vdc +10%/ ? 15% 110 vac 10% 230 vac 10% current consump- tion approx. 200 ma approx. 50 ma approx. 30 ma insulation class f (130 c max.) item led rated voltage 10 to 115 vac/vdc current leakage approx. 1 ma color (led) orange f502-en2-04.book seite 155 di enstag, 26. juli 2005 5:48 17
g-156 safety sensors / components characteristics note: 1. the above values are initial values. 2. the degree of protection is tested using t he method specified by the standard (en60947- 5-1). confirm that sealing properties ar e suffi- cient for the operating conditions and environment beforehand. although the switch box is protected from dust or water penetrat ion, do not use the d4nl in places where foreign material may penetrate through the key hole on the head, otherwise switch damage or ma l- functioning may occur. 3. the durability is for an ambient temperature of 5 c to 35 c and an ambient humidity of 40% to 70%. for more details, consult your om- ron representative. 4. if the ambient temperature is greater than 35 c, do not pass the 3-a, 250-vac load through more than 2 circuits. 5. these figures are minimum r equirements for safe operation. 6. this figure is based on the gs-et-19 evaluation method. 7. this value will vary with the switching frequency, environment, and reliability level. confirm that correct operation is possib le with the actual load beforehand. degree of protection (see note 2) ip67 (en60947-5-1) (this applies for the switch only. the degree of protection for the key hole is ip00.) durability (see note 3) mechanical 1,000,000 operations min. electrical 500,000 operations min. for a resistive load of 3 a at 250 vac (see note 4) operating speed 0.05 to 0.5 m/s operating frequency 30 operations/minute max. rated frequency 50/60 hz contact gap 2 x 2 mm min direct opening force (see note 5) 60 n min. (en60947-5-1) direct opening travel (see note 5) 10 mm min. (en60947-5-1) holding force (see note 6) 1,300 n min. insulation resistance 100 m ? min. (at 500 vdc) minimum applicable load (see note 7) resistive load of 1 ma at 5 vdc (n-level reference value) rated insulation voltage (u i ) 300 v (en60947-5-1) rated open thermal current (i th ) 10 a (en60947-5-1) impulse withstand voltage (en60947-5-1) between terminals of the same polarity 2.5 kv between terminals of different polarities 4 kv between other terminals and uncharged metallic parts 6 kv conditional short-circuit current 100 a (en60947-5-1) pollution degree (operating environment) 3 (en60947-5-1) protection against electric shock class ii (double insulation) contact resistance 25 m ? max. per contact (initial value) vibration resis- tance malfunction 10 to 55 hz, 0.75-mm single amplitude shock resistance destruction 1,000 m/s 2 min. malfunction 300 m/s 2 min. (100 m/s 2 min. for the lock monitor switch) ambient temperature operating: ? 10 c to 55 c with no icing ambient humidity operating:95% max. weight approx. 370 g (d4nl-iafa-b) f502-en2-04.book seite 156 di enstag, 26. juli 2005 5:48 17
g-157 d4nl d4nl connections indicator internal circuit diagram circuit connection example  terminals 12 and 41 are connected internally and so connect termi- nals 11 and 42 for safety-circuit input. (gs-et-19)  connect terminals 21 and 22 and terminals 51 and 52 in series when using as safety-circuit i nput (redundancy circuit for terminals 11 and 12 and terminals 41 and 42 above). connect the terminals individually when using as auxiliary -circuit input (e.g., terminals 21 and 22 for safety-door open/clos ed monitoring and terminals 51 and 52 for monitoring the lock status).  in the connection example on the right, terminals 21 and 22 and terminals 51 and 52 are used as auxiliary-circuit input.  direct opening contacts used as safe ty-circuit input are indicated with the mark. terminals 11 and 12 and terminals 21 and 22 are direct opening contacts.  connect the indicators in parallel to the auxiliary circuits or termi- nals e1 and e2. if an indicator is connected in paral lel to a direct opening contact, when the indicator breaks, a shor t-circuit current will be generated, possibly resulting in an installation malfunction.  do not switch standard loads for more than 2 circuits at the same time. otherwise, the level of insulation may decrease.  the 24-vdc solenoid has polarity. be sure to connect terminals with the correct polarity. d r r led z 10 to 115 vac/vdc constant-current diode 42 11 21 33 e1 (+) o1 o2 12 41 51 52 22 34 e2 ( ? ) indicator (orange) safety circuit auxiliary circuit auxiliary circuit auxiliary circuit f502-en2-04.book seite 157 di enstag, 26. juli 2005 5:48 17
g-158 safety sensors / components operation method operation principles nomenclature structure note: terminal numbers vary with the model. mechanical lock models when the operation key is inserted, it is locked by the lock spring. the door will stay locked even if there is a power interruption. the solenoid is released only when the lock is turned on. solenoid lock models if the solenoid is off, the door will not be locked when the operation key is inserted. this means that the door can be opened and closed easily when replacing work- pieces or parts. the door is locked only when the solenoid is turned on. this means that the door will be unlocked if there is a power interruption and so this model cannot be used in sys- tems that would maintain a hazardous state (e.g., systems requiring toxic gases, high temperatures, or gears that would continue to turn due to inertia). solenoid operation key lock plate spring off off on solenoid operation key lock plate spring off plunger off on special release key the head can be mounted in 3 directions. two conduits (horizontal and vertical) back-mounting is also possible. operation key hole terminal 42 terminal 41 shorting pin (12-41) terminal 12 terminal 11 door open/closed detection switch terminal 21 terminal 22 terminal 31/33 terminal 32/34 release key conduit opening (vertical) terminal 51/53 terminal 52/54 conduit opening (horizontal) lock monitor switch terminal 02 indicator terminal 01 terminal e1 (+ ) terminal e2 ( ? ) solenoid unlock lock unlock lock standard release key (bottom view) special release key (bottom view) f502-en2-04.book seite 158 di enstag, 26. juli 2005 5:48 17
g-159 d4nl d4nl contact form indicates conditions where the key is inserted and the lock is applied. terminals 12 and 41 are connected internally (as per gs -et-19). model contact contact form operating pattern remarks d4nl- @ af @ - @ 1nc/1no + 1nc/1no d4nl- @ bf @ - @ 1nc/1no + 2nc d4nl- @ cf @ - @ 2nc + 1nc/1no d4nl- @ df @ - @ 2nc + 2nc d4nl- @ ef @ - @ 2nc/1no + 1nc/1no d4nl- @ ff @ - @ 2nc/1no + 2nc d4nl- @ gf @ - @ 3nc + 1nc/1no d4nl- @ hf @ - @ 3nc + 2nc 11 33 34 12 41 42 54 53 11-42 33-34 53-54 on extraction completion position operation key insertion completion position stroke lock position only nc contacts 11- 12 and 41-42 have an approved direct opening mechanism. the terminals 11-42, 33- 34, and 53-54 can be used as unlike poles. 11 33 34 12 41 42 52 51 11-42 33-34 51-52 on extraction completion position operation key insertion completion position stroke lock position only nc contacts 11- 12, 41-42, and 51-52 have an approved direct opening mechanism. the terminals 11-42, 33- 34, and 51-52 can be used as unlike poles. 11 31 32 12 41 42 54 53 11-42 31-32 53-54 on extraction completion position operation key insertion completion position stroke lock position only nc contacts 11- 12, 31-32, and 41-42 have an approved direct opening mechanism. the terminals 11-42, 31- 32, and 53-54 can be used as unlike poles. 11 31 32 12 41 42 52 51 11-42 31-32 51-52 11-42 51-52 on extraction completion position operation key insertion completion position stroke lock position only nc contacts 11- 12, 31-32, 41-42, and 51-52 have an approved direct opening mechanism. the terminals 11-42, 31- 32, and 51-52 can be used as unlike poles. 11 21 22 33 34 12 41 42 54 53 11-42 21-22 33-34 53-54 11-42 21-22 33-34 53-54 on extraction completion position operation key insertion completion position stroke lock position only nc contacts 11- 12, 21-22, and 41-42 have an approved direct opening mechanism. the terminals 11-42, 21- 22, 33-34, and 53-54 can be used as unlike poles. 11 21 22 33 34 12 41 42 52 51 11-42 21-22 33-34 51-52 on extraction completion position operation key insertion completion position stroke lock position only nc contacts 11- 12, 21-22, 41-42, and 51-52 have an approved direct opening mechanism. the terminals 11-42, 21- 22, 33-34, and 51-52 can be used as unlike poles. 11 21 22 31 32 12 41 42 54 53 11-42 21-22 31-32 53-54 on extraction completion position operation key insertion completion position stroke lock position only nc contacts 11- 12, 21-22, 31-32, and 41-42 have an approved direct opening mechanism. the terminals 11-42, 21- 22, 31-32, and 53-54 can be used as unlike poles. 11 21 22 31 32 12 41 42 52 51 11-42 21-22 31-32 51-52 on extraction completion position operation key insertion completion position stroke lock position only nc contacts 11-12, 21-22, 31-32, 41-42 and 51-52 have an approved direct opening mechanism. the terminals 11-42, 21- 22, 31-32, and 51-52 can be used as unlike poles. f502-en2-04.book seite 159 di enstag, 26. juli 2005 5:48 17
g-160 safety sensors / components dimensions note: all units are in millimeter s unless otherwise indicated switches d4nl- @@@@ -b d4nl- @@@@ -b4 operating characteristics d4nl- @@@@ -b key insertion force key extraction force 15 n max. 30 n max. pre-travel distance 9 mm max. movement before being locked 3 mm min. operating characteristics d4nl- @@@@ -b4 key insertion force key extraction force 15 n max. 30 n max. pre-travel distance 9 mm max. movement before being locked 3 mm min. red black unloc k lock unloc k lock four, head mounting screws 30.5 15.5 pre-travel distance 8 15.3 10.5 4.4 28.5 59 (30.7) (57.9) 79 0.2 (88.5) 5 4.5 five, cover mounting screws (55.8) dummy cap indicator (13.3) 55 0.2 (95) (32.3) (3) 4 4 three, 4.3-dia. holes 6.5 6.5 29 cap screw 29 (15.3) conduit cap conduit opening release key (10) 35.5 0.5 0.5 6.5 29 32 0. 2 operation key red black unloc k lock unloc k lock four, head mounting screws 30.5 15.5 pre-travel distance 8 15.3 10.5 4.4 28.5 59 (30.7) (57.9) 79 0.2 (88.5) 5 4.5 five, cover mounting screws (55.8) dummy cap indicator (13.3) 55 0.2 (95) (32.3) (3) 4 4 three, 4.3-dia. holes 6.5 6.5 29 cap screw 29 conduit cap conduit opening release key (10) 35.5 0.5 0.5 6.5 29 32 0.2 operation key 8 21 10.5 releasing tool (provided) m8 hexagonal material or equivalent (15.3) f502-en2-04.book seite 160 di enstag, 26. juli 2005 5:48 17
g-161 d4nl d4nl d4nl- @@@@ -bs d4nl- @@@@ -b4s operation keys note: unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. operating characteristics d4nl- @@@@ -bs key insertion force key extraction force 15 n max. 30 n max. pre-travel distance 9 mm max. movement before being locked 3 mm min. red black unloc klock unloc k lock four, head mounting screws 30.5 15.5 pre-travel distance 8 15.3 10.5 4.4 28.5 59 (30.7) (57.9) 79 0.2 (88.5) 5 4.5 five, cover mounting screws (55.8) (31.5) release key indicator (13.3) 55 0.2 (95) (32.3) (3) 4 4 three, 4.3-dia. holes 6.5 6.5 29 cap screw 29 conduit cap conduit opening 35.5 0.5 0.5 6.5 29 32 0.2 (15.3) dummy cap operation key operating characteristics d4nl- @@@@ -b4s key insertion force key extraction force 15 n max. 30 n max. pre-travel distance 9 mm max. movement before being locked 3 mm min. r ed bl ack k k four, head mountin g screw s 1 pr e -tr a v e l d i s t a n ce 8 1 0 . 5 4. 4 28. 5 . . 59 ( 57.9 ) 79 5 ) 5 5 ) 55 5 ) 5 5 5 5 5 5 5 5 ) 5 ) 5 ) 30 15 7 17.5 28 4.3 13 2 13 7 d4ds-k1 four, 2.15r 3 30 13 15 24. 7 28 10.5 6 7 9 d4ds-k2 four, 2.15r 4 14 6.3 20 13 30 40 15 56 28 d4ds-k3 black 9 dia. 4.5 dia. 8 dia. d4ds-k5 black 4 20.9 28 24.6 22.5 43 41 55 30 8 1 (7) 6.5 13 15 18 f502-en2-04.book seite 161 di enstag, 26. juli 2005 5:48 17
g-162 safety sensors / components with operation key inserted d4nl + d4ds-k1 d4nl + d4ds-k3 d4nl + d4ds-k2 d4nl + d4ds-k5 red black (30.5) (30.5) (28.5) center tolerance of key hole: 1 44 min 46.5 max key insertion position 44 min 46.5 max key insertion position horizontal insertion radius: r 200 vertical insertion radius: r 200 15 center tolerance of key hole: 1 red black (30.5) 45 min 47.5 max key insertion position (30.5) 45 min 47.5 max key insertion position horizontal insertion radius: r 50 vertical insertion radius: r 200 center tolerance of key hole: 1 40 0.15 center tolerance of key hole: 1 (28.5) red black (30.5) 40 min 42.5 max key insertion position (30.5) 40 min 42.5 max key insertion position center tolerance of key hole: 1 15 horizontal insertion radius: r 200 vertical insertion radius: r 200 (6) (22.5) (28.5) center tolerance of key hole: 1 red black 43 0.1 (41 0.1 ) (30.5) 20.9 55 41 51.9 min 54.4 max key insertion position center tolerance of key hole: 1 horizontal insertion radius: r 50 vertical insertion radius: r 50 (30.5) 51.9 min 54.4 max key insertion position center tolerance of key hole: 1 (28.5) f502-en2-04.book seite 162 di enstag, 26. juli 2005 5:48 17
g-163 d4nl d4nl application examples g9sa-321-t @ (24 vac/vdc) + d4nl- @@@ a- @ , @@@ b- @ , @@@ c- @ (mechanical lock type) + d4d- @ 520n circuit diagram open s4 km1 km2 lock release signal s2 operation instruction motor controller off delay timer control circuit timing chart motor rotation off-delay time s1: safety limit switch with direct opening mechanism (d4n) s2: guard lock safety-door switch s3: reset switch s4: lock release switch km1 and km2: magnetic contactor m: 3-phase motor limit switch s1 reset switch s3 k1 and k2 (nc) k1 and k2 (no) k3 and k4 (nc) k3 and k4 (no) km1 and km2 (nc) km1 and km2 (no) operation instruction lock release signal lock release switch s4 stop signal guard opens guard can be opened stop signal 11 12 41 42 feedback loop guard lock safety-door switch s2 th sa f502-en2-04.book seite 163 di enstag, 26. juli 2005 5:48 17
g-164 safety sensors / components g9sa-301 (24 vac/vdc) + d4nl- @@@ g- @ , @@@ h- @ , @@@ j- @ (solenoid lock type) + d4d- @ 520n circuit diagram control circuit feedback loop operation instruction m km1 km2 motor controller s1 note: lock release is possible at any time. therefore, do not use the solenoid lock type in applications where the operator may be exposed to danger when the guard opens. use the mechanical lock type instead. timing chart limit switch s1 s1: safety limit switch with direct opening mechanism (d4n) s2: guard lock safety-door switch km1 and km2: magnetic contactor m: 3-phase motor guard lock safety-door switch s2 operation signal lock signal k1 and k2 (nc) k1 and k2 (no) km1 and km2 (nc) km1 and km2 (no) guard opens th sa 31 32 s2 open 12 11 lock signal operation signal f502-en2-04.book seite 164 di enstag, 26. juli 2005 5:48 17
g-165 d4nl d4nl precautions !caution do not insert the operation key with the door open. the machine may operate and damage may result. !caution do not use metal connectors or c onduits with this switch. damage to the broken conduit hole may cause electric shock. !caution change the head direction after changing the release key to the unlock position. do not change the head direction with the cov- er removed. failure to observe these points may result in switch malfunction or damage. holding force  do not apply a force exceeding the specified holding force. doing so may break the switch and the machine may continue to operate.  either install another locking com ponent (e.g., a stop) in addition to the switch, or use a warning sti cker or an indicator showing the lock status so that a force ex ceeding the specified holding force is not applied. safety precautions  the switch contacts can be us ed for either standard loads or microloads. once a contact has been used to switch a standard load, however, it cannot be used for a load of a smaller capacity. doing so may result in roughening of the contact surface and con- tact reliability may be lost.  turn off the power before disassembling the switch or touching any internal parts. not doing so may result in electric shock.  mount the operation key in a location where it will not come in con- tact with users when the door is opened or closed. otherwise, injury may result.  do not impose excessive force on the operation key when it is inserted into the switch or drop the switch with the operation key inserted. otherwise, the operation key may be deformed or the switch may be broken.  observe the specified insertion radius for the operation key and insert it in a direction perpendicular to the key hole.  do not use the switch in starting ci rcuits. (use for safety confirma- tion signals.)  when using the switch in emergenc y-stop circuits or other safety circuits that have a direct impact on human lives, operate the nc contacts that have a direct opening mechanism in direct opening mode. for safety purposes, prevent easy removal by, for example, mounting the switch and operation key with one-way screws or attaching a protective cover and warning label.  in order to prevent short-circui t damage to the switch, connect a fuse to the switch in series. use a fuse with a breaking current of 1.5 to 2 times the rated current. to conform to en ratings, use a iec269-compliant 10-a fuse type gi or gg .  turn the power off when wiring. after wiring is completed, be sure to mount the cover before use.  in order to prevent burning due to overvoltage, insert a protective fuse in the solenoid circuits.  do not use the switch where explosive gas, flammable gas, or any other dangerous gas may be present.  ensure that the load current does not exceed the rated current.  be sure to wire the terminals correctly.  be sure to evaluate the switch under actual operating conditions after installation.  do not drop the package or the product. do not disassemble inter- nal parts. release key  the release key is used to unlock the switch in case of emergency or if the power supply to the switch stops.  if the release key setting is cha nged from lock to unlock using an appropriate tool, the lock will be released and the safety door can be opened (mechanical lock models only).  after setting the release key to unlock in order to, for example, change the head direction or perform maintenance, be sure to return it to lock setting before resuming operation.  when the switch is used for the door of a machine room to ensure the safety of people performing adjustment work inside, if the release key is set to unlock, the door will not be locked when the door is closed and no power wi ll be supplied to the equipment.  do not use the release key to start or stop machines.  the auxiliary lock must only be released by authorized personnel.  do not impose a force exceeding 1 nm on the release key screws. the release key may be damaged and may not operated properly.  to prevent the release key from being used by unauthorized per- sonnel, set it to lock and seal it with seal wax. mounting  do not use the switch as a stopper. to prevent the door from com- ing into contact with the flange of the operation key, be sure to mount the switch with a stopper as shown above.  when the switch is used for a hinged door at a location near to the hinged side, where the operation key?s insertion radius is compar- atively small, if an attempt is made to open the door beyond the lock position, the force imposed will be much larger than for loca- tions far from the hinged side, and the lock may be damaged. solenoid lock models the solenoid lock locks the door only when power is supplied to the solenoid. therefore, the door will be unlocked if the power supply to the solenoid stops. therefore, do not use solenoid lock models for machines that may be operating and dangerous even after the machine stops operating. unlock lock switch operation key door stopper set zone (0.5 to 3 mm) f502-en2-04.book seite 165 di enstag, 26. juli 2005 5:48 17
g-166 safety sensors / components correct use operating environment  this switch is for indoor use only. do not use it outdoors. other- wise, it may malfunction.  do not use the switch in the following locations:  locations subject to severe temperature changes  locations subject to high hum idity levels or condensation  locations subject to severe shocks or vibrations  locations where the switch may come in contact with metal dust, oil, or chemicals  locations subject to thinner, detergent, or other solvents.  although the switch itself is protected from dust or water penetra- tion, ensure that foreign material does not penetrate through the key hole on the head, otherwise switch damage or malfunctioning may occur.  do not use the switch submerged in oil or water, or in locations continuously subject to splashes of oil or water. doing so may result in oil or water entering the switch interior. (the ip67 degree of pro- tection specification for the switch pertains to the amount of water penetration after the switch is submerged in water for a certain period of time.) life expectancy the life expectancy of the switch w ill vary with the switching condi- tions. before applying the switch, test it under actual operating con- ditions and be sure to use it at a switching frequency that will not lower its performance. operation key  use the designated omron operation key with the switch. using another operation key may result in switch damage.  do not impose excessive force on the operation key when it is inserted into the switch or drop the switch with the operation key inserted. otherwise, the operation key may be deformed or the switch may be broken. mounting tightening torque be sure to tighten each screw of the switch properly. loose screws may result in malfunction. switch and operation key mounting  mount the switch and operation key securely to the applicable tightening torque with m4 screws. ]  if the switch is back-mounted, the release key can only be oper- ated from the bottom and the indicator cannot be used.  use the designated omron operation key with the switch. using another operation key may result in switch damage.  ensure that the alignment offset between the operation key and the key hole does not exceed 1 mm. head direction by removing the four screws of the head, the mounting direction of the head can be changed. the head can be mounted in four direc- tions. ensure that no foreign matter penetrates the interior of the switch. securing the door when the door is closed (with the operation key inserted), it may be pulled beyond the set zone because of, for example, the door?s weight, or the door cushion rubber. also, if a load is applied to the operation key, the door may fail to unlock properly. use hooks to ensure that the door stays within the set zone (0.5 to 3 mm). type tightening torque terminal screw 0.59 to 0.78 nm cover mounting screw 0.49 to 0.69 nm head mounting screw 0.49 to 0.59 nm operation key mounting screw 2.35 to 2.75 nm switch mounting screw 0.49 to 0.69 nm connector 1.77 to 2.16 nm cap screw 1.27 to 1.67 nm applying weight dropping d4ds-k1/-k2 (horizontal/vertical mounting) d4ds-k3 (adjustable mounting: horizontal) d4ds-k5 (adjustable mounting: vertical) 40 0.1 two, m4 15 0.1 two, m4 mounting hole dimensions for switch mounting hole dimensions for operation key three, m4 79 0.1 32 0.1 55 0.1 41 0.1 or, 43 0.1 two, m4 operation key set zone (0.5 to 3 mm) f502-en2-04.book seite 166 di enstag, 26. juli 2005 5:48 17
g-167 d4nl d4nl wiring wiring precautions  when connecting to the terminals via insulating tube and m3.5 crimp terminals, cross the crimp terminals as shown above so that they do not rise up onto the case or the cover. applicable lead wire size: awg20 to awg18 (0.5 to 0.75mm 2 ).  when connecting lead wires directly to terminals, perform wiring securely so that there are no loose wire strands.  do not push crimp terminals into gaps in the case interior. doing so may cause damage or deformation of the case.  use lead wires of an appropriate length. not doing so may cause the cover to rise.  use crimp terminals not more than 0.5 mm in thickness. otherwise, they will interfere with other components inside the case. the crimp terminals shown below are not more than 0.5 mm thick. conduit opening  connect a recommended connector to the opening of the conduit and tighten the connector to the proper torque. the case may be damaged if an excessive tightening torque is applied.  in order to ensure ip67 degree of protection, wrap sealing tape around the conduit end of the connector.  be sure that the outer diameter of the cable connected to the con- nector is correct.  attach and tighten a conduit cap to the unused conduit opening when wiring. the conduit cap is provided with the switch. recommended connectors use a connector with a screw section not exceeding 11 mm, other- wise the screws will protrude into the case interior. the connectors given in the following table have connectors with screw sections not exceeding 11 mm. use the following connectors to ensure conformance to ip67. use lapp connectors together with seal packing (jpk-16, gp-13.5, or gpm20), and tighten with the applicable torque. seal packing is sold separately. maintenance and repairs the user must not perform repai rs or maintenance. contact the machine manufacturer if repai rs or maintenance are required. storage do not store the switch in locations where harmful gases (e.g., h 2 s, so 2 , nh 3 , hno 3 , or cl 2 ) or dust are present, or in locations subject to high humidity levels. miscellaneous  do not touch the solenoid. the temperature of the solenoid increases when current is passed.  in conditions requiring greater ri gidity, sealing performance, and oil resistance, use omron?s d4bl.  perform regular inspections. manufacturer model j.s.t. fv0.5-3.7 11 22 21 34 33 12 l l f b d dz t: 0.5 mm dz dia.: 3.7 mm d dia.: 2.9 mm b: 6.6 mm l: 19 mm f: 7.7 mm i : 8.0 mm terminal screw crimp terminal size manufacturer model applicable cable diameter g 1 / 2 lapp st-pf1/2 5380-1002 6.0 to 12.0 mm ohm denki oa-w1609 7.0 to 9.0 mm oa-w1611 9.0 to 11.0 mm pg13.5 lapp s-13.5 5301-5030 5.0 to 12.0 mm m20 lapp st-m20 * 1.5 5311-1020 7.0 to 13.0 mm f502-en2-04.book seite 167 di enstag, 26. juli 2005 5:48 17
g-168 safety sensors / components production termination following the release of the d4nl , production of the d4dl will be terminated. date of production termination production of the d4dl series will be terminated in november 2003. date of substitute product release sale of the d4nl series commenced in october 2002. product replacement the d4dl and d4nl have basically the same structure, and use the same mounting method and operation keys. there are differences, however, in the external appearance and the mounting sections. comparison of the d4dl and substitute products dimensions differences:the depth of the m4 mounting screw holes is 29 mm for the d4nl, as opposed to 10 mm for the d4dl. there- fore, when replacing the d4dl with the d4nl, use m4 screws that are 19 mm longer than the ones used before. model d4nl- @ switch color ver y similar dimensions ver y similar wiring/connection significantly different mounting method ver y similar ratings/performance ver y similar operating characteristics ver y similar operating method completely compatible discon- tinued model (d4dl) re- place- ment prod- ucts (d4nl series) cap screw indicator conduit cap release key 35 10 three, 4.3-dia. holes 55 0.2 32 0.2 (59) 79 0.2 5 (88.5) (95) 10 8 15.5 30.5 10 (21) (28.8) (25.1) (32.3) (15.3) (3) 4 4 4.5 10.5 15.3 4.4 28.5 59 (37) operation key cap head unlock lock unlock lock 30.5 15.5 8 15.3 10.5 4.4 28.5 a 59 (30.7) (57.9) 79 0.2 (88.5) 5 4.5 (55.8) dummy cap indicator (13.3) 55 0.2 (95) (32.3) (3) 4 4 three, 4.3-dia. holes 6.5 6.5 29 cap screw 29 (15.3) conduit cap release key (10) 35.5 0.5 0.5 6.5 29 32 0.2 operation key cap head the above diagram is for switches with the release key on the bottom. for switches with the release key on the front, interchan g e the positions of the release key and dummy cap (a). f502-en2-04.book seite 168 di enstag, 26. juli 2005 5:48 17
g-169 d4nl d4nl list of recommended substitute products switch note: with standard products, terminals 12 and 41 are connected with a short- ing pin. in cases where d4dl terminals 11 and 12 and terminals 41 and 42 are currently being used independently, remove the shorting pin. note: operation key  d4ds-k1  d4ds-k2  d4ds-k3  d4ds-k5 all of the above operation keys can be used with the d4nl. d4dl product recommended substitute product substitute with m20 conduit d4dl-1cfa-b d4nl-1afa-b, d4nl-1bfa-b d4nl-4afa-b, d4nl-4bfa-b d4dl-2cfa-b d4nl-2afa-b, d4nl-2bfa-b d4dl-1dfa-b d4nl-1cfa-b, d4nl-1dfa-b d4nl-4cfa-b, d4nl-4dfa-b d4dl-2dfa-b d4nl-2cfa-b, d4nl-2dfa-b d4dl-1cfg-b d4nl-1afg-b, d4nl-1bfg-b d4nl-4afg-b, d4nl-4bfg-b d4dl-2cfg-b d4nl-2afg-b, d4nl-2bfg-b d4dl-1dfg-b d4nl-1cfg-b, D4NL-1DFG-B d4nl-4cfg-b, d4nl-4dfg-b d4dl-2dfg-b d4nl-2cfg-b, d4nl-2dfg-b d4dl-1cfb-b d4nl-1afb-b, d4nl-1bfb-b d4nl-4afb-b, d4nl-4bfb-b d4dl-2cfb-b d4nl-2afb-b, d4nl-2bfb-b d4dl-1dfb-b d4nl-1cfb-b, d4nl-1dfb-b d4nl-4cfb-b, d4nl-4dfb-b d4dl-2dfb-b d4nl-2cfb-b, d4nl-2dfb-b d4dl-1cfh-b d4nl-1afh-b, d4nl-1bfh-b d4nl-4afh-b, d4nl-4bfh-b d4dl-2cfh-b d4nl-2afh-b, d4nl-2bfh-b d4dl-1dfh-b d4nl-1cfh-b, d4nl-1dfh-b d4nl-4cfh-b, d4nl-4dfh-b d4dl-2dfh-b d4nl-2cfh-b, d4nl-2dfh-b d4dl-1cfc-ew d4nl-1afc-e, d4nl-1bfc-e d4nl-4afc-e, d4nl-4bfc-e d4dl-2cfc-ew d4nl-2afc-e, d4nl-2bfc-e d4dl-1dfc-ew d4nl-1cfc-e, d4nl-1dfc-e d4nl-4cfc-e, d4nl-4dfc-e d4dl-2dfc-ew d4nl-2cfc-e, d4nl-2dfc-e d4dl-1cfj-ew d4nl-1afj-e, d4nl-1bfj-e d4nl-4afj-e, d4nl-4bfj-e d4dl-2cfj-ew d4nl-2afj-e, d4nl-2bfj-e d4dl-1dfj-ew d4nl-1cfj-e, d4nl-1dfj-e d4nl-4cfj-e, d4nl-4dfj-e d4dl-2dfj-ew d4nl-2cfj-e, d4nl-2dfj-e d4dl-1cfa-b-ht d4nl-1afa-b4, d4nl-1bfa-b4 d4nl-4afa-b4, d4nl-4bfa-b4 d4dl-2cfa-b-ht d4nl-2afa-b4, d4nl-2bfa-b4 d4dl-1dfa-b-ht d4nl-1cfa-b4, d4nl-1dfa-b4 d4nl-4cfa-b4, d4nl-4dfa-b4 d4dl-2dfa-b-ht d4nl-2cfa-b4, d4nl-2dfa-b4 d4dl-1cfg-b-ht d4nl-1afg-b4, d4nl-1bfg-b4 d4nl-4afg-b4, d4nl-4bfg-b4 d4dl-2cfg-b-ht d4nl-2afg-b4, d4nl-2bfg-b4 d4dl-1dfg-b-ht d4nl-1cfg-b4, D4NL-1DFG-B4 d4nl-4cfg-b4, d4nl-4dfg-b4 d4dl-2dfg-b-ht d4nl-2cfg-b4, d4nl-2dfg-b4 f502-en2-04.book seite 169 di enstag, 26. juli 2005 5:48 17
g-170 safety sensors / components in the interest of product improvement, specif ications are subject to change without notice. all dimensions shown are in millimeters. to convert millimeters into inches, multiply by 0.03 937. to convert grams into ounces, multiply by 0.03527. cat. no. c126-e2-01-x f502-en2-04.book seite 170 di enstag, 26. juli 2005 5:48 17


▲Up To Search▲   

 